Zemic B3G

د.إ0



Datasheet

Stainless steel IP67, “S” type load cell

Tension and compression applications

Suitable for hanging, hopper and other weighing devices

Also available in imperial capacities and dimensions

Compare
SKU: 111202 Categories: , , ,
Description

Zemic B3G Introduction

The Zemic B3G is a stainless‑steel universal load cell designed for accurate tension and compression measurements. Its S‑type geometry ensures a clean, centered force path, making the loadcell highly stable and reliable under repeated loading cycles. With IP67 protection, C3 accuracy, and capacities ranging from 50 kg up to 10 tons, the B3G stands out as a versatile choice for industrial environments that demand durability, precision, and easy integration. Whether used as a single sensor or part of a larger weighing system, it delivers consistent performance that many engineers rely on when selecting quality load cells.

Zemic B3G Introduction Loadcell.ae

Installation

Proper installation directly affects the accuracy and lifetime of the loadcell:

1- Mount the load cell in a perfectly vertical line with the applied force to avoid bending or side loads.
2- Use the correct metric threads according to the rated capacity (M8 to M30) and apply the recommended torque to avoid mechanical distortion.
3- Ensure both the upper and lower mounting points are aligned. Misalignment can introduce unwanted stresses that degrade long‑term repeatability.
4- Allow slight mechanical freedom so the sensor body can deflect naturally; avoid overly rigid or welded connections.

If used outdoors or in high‑moisture areas, route the cable downward to reduce the risk of water ingress despite the IP67 rating.

Zemic B3G Installation Loadcell.ae

Loading

To achieve optimal performance:

1- Apply force directly along the centerline of the Zemic B3G loadcell.
2- For tension applications, use compatible accessories such as eye bolts or rod ends to keep the load path straight.
3- For compression, ensure flat, stable contact surfaces aligned with the sensor’s geometry.
4- Avoid lateral loads, twisting forces, or impact shocks, even though the load cell supports 150% safe overload and 300% ultimate overload.
5- After installation, let the sensor settle, then perform zeroing and calibration for the most accurate readings.

Zemic B3G Loading Loadcell.ae

Applications

  • Perfect for systems requiring a universal load cell capable of both tension and compression measurement.
  • Ideal for industrial setups that depend on high‑precision load cells for force monitoring and process automation.
  • Reliable choice for production lines, batching equipment, and systems needing a rugged Zemic loadcell with high overload tolerance.
  • Suitable for hanging, hopper and other weighing devices, providing accurate vertical load transfer.
  • Useful in conveyor scales, suspended weighing mechanisms, crane tension monitoring, and mechanical‑to‑digital retrofit projects.
  • Highly effective in automated industrial machinery requiring stable, repeatable feedback from a stainless‑steel load cell.
Crane Scales Application Loadcell.ae

Various Types of hanging scales such as crane scales and hanging scales

Overhead Track Scales Application Loadcell.ae

Various Types of ceiling weighing, such as fixed and mobile ceiling crane weighing, elevator and hoist weighing, slaughterhouse and slaughterhouse ceiling weighing, and medical equipment ceiling weighing.

Tension Compression Measurements Application Loadcell.ae

Measurement of compression or tension force such as force testing device

Batching Blending Mixing Scales Application Loadcell.ae

Various types of batching and mixers weighing for asphalt factories, concrete factories, food industries, pharmaceutical industries and petrochemical industries.

Zemic B3G Dimensions (mm)

Zemic B3G Dimensions Loadcell.ae
Zemic B3G Dimensions Table Loadcell.ae

Wiring

The B3G uses a standard 4‑wire shielded cable:

Red — Input (+)

Black — Input (–)

Green — Output (+)

White — Output (–)

The polyurethane-jacketed cable is industrial‑grade and shielded for noise protection. For best performance, ground the shield at the instrumentation end only.

Red-White-Black-Green-Wiring-LoadcellAe

Zemic B3G Standards

OIML Standard Loadcell.ae
OIML
ATEX Standard Loadcell.ae
ATEX
NTEP Standard Loadcell.ae
NTEP
FM Standard Loadcell.ae
FM
CE Standard Loadcell.ae
CE
PCT Standard Loadcell.ae
PCT
RoHS Standard Loadcell.ae
RoHS
IP67 Standard Loadcell.ae
IP67
Additional information
BrandZemic
TypeUniversal
Elemental MaterialStainless Steel
IP (Ingress Protection)IP67
Capacity0.05 t, 0.1 t, 0.25 t, 0.5 t, 1 t, 10 t, 2.5 t, 5 t, 7.5 t
Accuracy ClassC3
Maximum Intervals3000
Minimum Verification Interval10000, 12000, 7000
Output Sensitivity3.0 ± 0.008
Zero Balance1.0
Input Resistance430 ± 50
Output Resistance351 ± 2
Excitation Voltage5 ~ 12
Compensated Temperature-10 ~+ 40
Safe Overload150
Ultimate Overload300
Dimensions (mm)50.8 x (15.06/21.41/27.76) x 60.96 / 76.2 x 27.76 x 99.06 / 74.68 x 34.12 x 99.06 / 87.38 x 40.46 x 139.7 / 112.78 x 46.31 x 177.8