Celltec PA5
د.إ0
Aluminium-Alloy IP65 single point load cell
Colorless anodized
Suitable for single and double load cell structured platform scales
Maximum platform size: 40 x 40 cm
Celltec PA5 Introduction
The Celltec PA5 load cell stands out as one of the most robust single-point load cells available. It features four screws at both the top and bottom, making it a reliable choice for various commercial scales with capacities ranging from 50 to 300 kilograms. The PA5 load cell is widely used in the weighing industry due to its compact physical size, straightforward installation process, and satisfactory quality and accuracy.
Here are the key details about the Celltec PA5 load cell:
1-Capacity: It can handle weights between 50 and 300 kilograms.
2-Accuracy Class: The PA5 load cell falls into the C3 accuracy class.
3-Material: Constructed from anodized aluminum alloy.
4-Protection Rating: It boasts an IP65 protection rating, making it suitable for use in industrial environments.
The load cell’s dimensions are up to 40×40 centimeters, with no weight difference on the sides. Additionally, a special strong adhesive secures the strain gauges at the connection point. This load cell’s robustness and protection make it ideal for industrial applications.
Applications of the Celltec PA5 load cell include:
1-Commercial Scales
2-Industrial Scales
3-Medical Scales
4-Veterinary Scales
5-Laboratory Scales
Whether you need accurate measurements for commercial purposes or scientific research, the Celltec PA5 load cell is a reliable and user-friendly choice. 📊🔍

Installation

Loading

Celltec PA5 Applications

All types of single point scales such as store and retail scales, piece counter scales, postal scales, airport scales, household scales, medical scales, laboratory scales, labeling scales, bar code reading scales and industrial scales.

Various types of Hopper weighing for food and chemical industries

Various types of single point belt scales such as conveyor belt weighing, roller weighing and production line controller weighing.

Celltec PA5 Dimensions (mm)


Wiring

Celltec PA5 Standards






Brand |
Celltec |
---|---|
Capacity |
100kg ,150kg ,200kg ,250kg ,300kg ,50kg |
IP (Ingress Protection) |
IP65 |
Class |
C3 ,C5 |
Elemental Material |
Alloy Steel |
Maximum Intervals |
3000 ,5000 |
Minimum Verification Interval |
10000 ,20000 |
Output Sensitivity |
2.0 ± 0.3 |
Zero Balance |
2.0 |
Input Resistance |
405 ± 5 |
Output Resistance |
350 ± 3.5 |
Excitation Voltage |
5 ~ 15 |
Compensated Temperature |
-10 ~+ 40 |
Safe Overload |
150 |
Ultimate Overload |
300 |