Celltec PA3 Introduction
The Celltec PA3 load cell is widely used across various industries, particularly in the packaging sector, owing to its versatile installation capabilities. With exceptional accuracy and a minimum of 10,000 divisions within the C3 accuracy class, most users find its performance highly satisfactory. Notably, this load cell features force support edges at both the top and bottom, eliminating the need for additional shimming during installation.
Key details about the PA3 load cell include:
1-Single-Point Design: Calibrated by the manufacturer, the PA3 load cell falls within the accuracy class (C3). It maintains consistent weight distribution across its maximum dimensions of 40×40 centimeters.
2-Material and Durability: Crafted from anodized aluminum alloy, the load cell ensures longevity. The strain gauge junction is securely filled with a special resistant resin.
3-IP65 Protection: Boasting an IP65 protection rating, the PA3 load cell is well-suited for use in industrial environments, providing dust-tightness and safeguarding against water exposure.
In summary, the Celltec PA3 load cell offers the following benefits:
1-Versatility: Ideal for various industries, including packaging.
2-Accuracy: Precise measurements with a high division count.
3-Durability: Anodized aluminum construction ensures longevity.
4-Industrial Suitability: IP65-rated protection for challenging environments.
Feel free to reach out if you have any further questions! 🌟


Installation



Loading

Celltec PA3 Applications

All types of single point scales such as store and retail scales, piece counter scales, postal scales, airport scales, household scales, medical scales, laboratory scales, labeling scales, bar code reading scales and industrial scales.

Various types of single point belt scales such as conveyor belt weighing, roller weighing and production line controller weighing.

Celltec PA3 Dimensions (mm)

Wiring

Celltec PA3 Standards






Brand |
Celltec |
---|---|
Capacity |
100kg ,10kg ,15kg ,20kg ,30kg ,50kg ,5kg ,75kg |
Class |
C3 ,C4 |
Elemental Material |
Alloy Steel |
Minimum Verification Interval |
10000 ,20000 |
Output Sensitivity |
2.0 ± 0.3 |
Zero Balance |
2.0 |
Input Resistance |
410 ± 5 |
Output Resistance |
350 ± 3.5 |
Excitation Voltage |
5 ~ 15 |
Compensated Temperature |
-10 ~+ 40 |
Safe Overload |
150 |
Ultimate Overload |
300 |